1.
Vaccines (Basel) ; 11(3)2023 Mar 06.
Article in English | MEDLINE | ID: covidwho-2267372

ABSTRACT

(1) Background: The high incidence of SARS-CoV-2 infection in vaccinated persons underscores the importance of individualized re-vaccination. PanIg antibodies that act against the S1/-receptor binding domain quantified in serum by a routine diagnostic test (ECLIA, Roche) can be used to gauge the individual ex vivo capacity of SARS-CoV-2 neutralization. However, that test is not adapted to mutations in the S1/-receptor binding domain, having accumulated in SARS-CoV-2 variants. Therefore, it might be unsuited to determine immune-reactivity against SARS-CoV-2 BA.5.1. (2) Method: To address this concern, we re-investigated sera obtained six months after second vaccinations with un-adapted mRNA vaccine Spikevax (Moderna). We related serum levels of panIg against the S1/-receptor binding domain quantified by the un-adapted ECLIA with full virus neutralization capacity against SARS-CoV-2 B.1 or SARS-CoV-2 BA5.1. (3) Results: 92% of the sera exhibited sufficient neutralization capacity against the B.1 strain. Only 20% of the sera sufficiently inhibited the BA5.1 strain. Sera inhibiting BA5.1 could not be distinguished from non-inhibiting sera by serum levels of panIg against the S1/-receptor binding domain quantified by the un-adapted ECLIA. (4) Conclusion: Quantitative serological tests for an antibody against the S1/-receptor binding domain are unsuited as vaccination companion diagnostics, unless they are regularly adapted to mutations that have accumulated in that domain.

2.
J Pediatr ; 257: 113358, 2023 06.
Article in English | MEDLINE | ID: covidwho-2271796

ABSTRACT

Using an electronic health record-based algorithm, we identified children with Coronavirus disease 2019 (COVID-19) based exclusively on serologic testing between March 2020 and April 2022. Compared with the 131 537 polymerase chain reaction-positive children, the 2714 serology-positive children were more likely to be inpatients (24% vs 2%), to have a chronic condition (37% vs 24%), and to have a diagnosis of multisystem inflammatory syndrome in children (23% vs <1%). Identification of children who could have been asymptomatic or paucisymptomatic and not tested is critical to define the burden of post-acute sequelae of severe acute respiratory syndrome coronavirus 2 infection in children.


Subject(s)
COVID-19 , Humans , Child , COVID-19/complications , COVID-19/diagnosis , Post-Acute COVID-19 Syndrome , SARS-CoV-2 , Cohort Studies , Electronic Health Records , Antibodies, Viral , Disease Progression , COVID-19 Testing
3.
Anal Bioanal Chem ; 2022 Nov 08.
Article in English | MEDLINE | ID: covidwho-2242236

ABSTRACT

The SARS-CoV-2 pandemic has shown the importance of rapid and comprehensive diagnostic tools. While there are numerous rapid antigen tests available, rapid serological assays for the detection of neutralizing antibodies are and will be needed to determine not only the amount of antibodies formed after infection or vaccination but also their neutralizing potential, preventing the cell entry of SARS-CoV-2. Current active-virus neutralization assays require biosafety level 3 facilities, while virus-free surrogate assays are more versatile in applications, but still take typically several hours until results are available. To overcome these disadvantages, we developed a competitive chemiluminescence immunoassay that enables the detection of neutralizing SARS-CoV-2 antibodies within 7 min. The neutralizing antibodies bind to the viral receptor binding domain (RBD) and inhibit the binding to the human angiotensin-converting enzyme 2 (ACE2) receptor. This competitive binding inhibition test was characterized with a set of 80 samples, which could all be classified correctly. The assay results favorably compare to those obtained with a more time-intensive ELISA-based neutralization test and a commercial surrogate neutralization assay. Our test could further be used to detect individuals with a high total IgG antibody titer, but only a low neutralizing titer, as well as for monitoring neutralizing antibodies after vaccinations. This effective performance in SARS-CoV-2 seromonitoring delineates the potential for the test to be adapted to other diseases in the future.

4.
Anal Bioanal Chem ; 413(22): 5619-5632, 2021 Sep.
Article in English | MEDLINE | ID: covidwho-2174032

ABSTRACT

In the face of the COVID-19 pandemic, the need for rapid serological tests that allow multiplexing emerged, as antibody seropositivity can instruct about individual immunity after an infection with SARS-CoV-2 or after vaccination. As many commercial antibody tests are either time-consuming or tend to produce false negative or false positive results when only one antigen is considered, we developed an automated, flow-based chemiluminescence microarray immunoassay (CL-MIA) that allows for the detection of IgG antibodies to SARS-CoV-2 receptor-binding domain (RBD), spike protein (S1 fragment), and nucleocapsid protein (N) in human serum and plasma in less than 8 min. The CoVRapid CL-MIA was tested with a set of 65 SARS-CoV-2 serology positive or negative samples, resulting in 100% diagnostic specificity and 100% diagnostic sensitivity, thus even outcompeting commercial tests run on the same sample set. Additionally, the prospect of future quantitative assessments (i.e., quantifying the level of antibodies) was demonstrated. Due to the fully automated process, the test can easily be operated in hospitals, medical practices, or vaccination centers, offering a valuable tool for COVID-19 serosurveillance. Graphical abstract.


Subject(s)
Antibodies, Viral/blood , COVID-19 Serological Testing/methods , Immunoassay/methods , Immunoglobulin G/blood , SARS-CoV-2/immunology , Antigens, Viral/chemistry , Antigens, Viral/immunology , Automation, Laboratory , Coronavirus Nucleocapsid Proteins/immunology , Humans , Immobilized Proteins/chemistry , Immobilized Proteins/immunology , Immune Sera , Immunoassay/instrumentation , Lab-On-A-Chip Devices , Luminescent Measurements , Phosphoproteins/immunology , Sensitivity and Specificity , Spike Glycoprotein, Coronavirus/genetics , Spike Glycoprotein, Coronavirus/immunology , Time Factors
5.
Biotechnol Rep (Amst) ; 37: e00780, 2023 Mar.
Article in English | MEDLINE | ID: covidwho-2165122

ABSTRACT

SARS-CoV-2 receptor binding domain (RBD) recognizes the angiotensin converting enzyme 2 (ACE2) receptor in host cells that enables infection. Due to its antigenic specificity, RBD production is important for development of serological assays. Here we have established a system for stable RBD production in HEK 293T mammalian cells that simultaneously express the recombinant fluorescent protein dTomato, which enables kinetic monitoring of RBD expression by fluorescence microscopy. In addition, we have validated the use of this recombinant RBD in an ELISA assay for the detection of anti-RBD antibodies in serum samples of COVID-19 convalescent patients. Recombinant RBD generated using this approach can be useful for generation of antibody-based therapeutics against SARS-CoV-2, as well serological assays aimed to test antibody responses to this relevant virus.

6.
Biosens Bioelectron ; 213: 114476, 2022 Oct 01.
Article in English | MEDLINE | ID: covidwho-1944329

ABSTRACT

Coronavirus disease 2019 (COVID-19) has caused significant global morbidity and mortality. The serology test that detects antibodies against the disease causative agent, the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has often neglected value in supporting immunization policies and therapeutic decision-making. The ELISA-based antibody test is time-consuming and bulky. This work described a gold micro-interdigitated electrodes (IDE) biosensor for COVID antibody detection based on Electrochemical Impedance Spectroscopy (EIS) responses. The IDE architecture allows easy surface modification with the viral structure protein, Spike (S) protein, in the gap of the electrode digits to selectively capture anti-S antibodies in buffer solutions or human sera. Two strategies were employed to resolve the low sensitivity issue of non-faradic impedimetric sensors and the sensor fouling phenomenon when using the serum. One uses secondary antibody-gold nanoparticle (AuNP) conjugates to further distinguish anti-S antibodies from the non-specific binding and obtain a more significant impedance change. The second strategy consists of increasing the concentration of target antibodies in the gap of IDEs by inducing an AC electrokinetic effect such as dielectrophoresis (DEP). AuNP and DEP methods reached a limit of detection of 200 ng/mL and 2 µg/mL, respectively using purified antibodies in buffer, while the DEP method achieved a faster testing time of only 30 min. Both strategies could qualitatively distinguish COVID-19 antibody-positive and -negative sera. Our work, especially the impedimetric detection of COVID-19 antibodies under the assistance of the DEP force presents a promising path toward rapid, point-of-care solutions for COVID-19 serology tests.


Subject(s)
Biosensing Techniques , COVID-19 , Metal Nanoparticles , Biosensing Techniques/methods , COVID-19/diagnosis , Electrodes , Gold/chemistry , Humans , Metal Nanoparticles/chemistry , SARS-CoV-2
7.
Vaccines (Basel) ; 10(7)2022 Jun 29.
Article in English | MEDLINE | ID: covidwho-1917858

ABSTRACT

PURPOSE: We describe a diagnostic procedure suitable for scheduling (re-)vaccination against severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2) according to individual state of humoral immunization. METHODS: To clarify the relation between quantitative antibody measurements and humoral ex vivo immune responsiveness, we monitored 124 individuals before, during and six months after vaccination with Spikevax (Moderna, Cambridge, MA, USA). Antibodies against SARS-CoV-2 spike (S1) protein receptor-binding domain (S1-AB) and against nucleocapsid antigens were measured by chemiluminescent immunoassay (Roche). Virus-neutralizing activities were determined by surrogate assays (NeutraLISA, Euroimmune; cPass, GenScript). Neutralization of SARS-CoV-2 in cell culture (full virus NT) served as an ex vivo correlate for humoral immune responsiveness. RESULTS: Vaccination responses varied considerably. Six months after the second vaccination, participants still positive for the full virus NT were safely determined by S1-AB levels ≥1000 U/mL. The full virus NT-positive fraction of participants with S1-AB levels <1000 U/mL was identified by virus-neutralizing activities >70% as determined by surrogate assays (NeutraLISA or cPas). Participants that were full virus NT-negative and presumably insufficiently protected could thus be identified by a sensitivity of >83% and a specificity of >95%. CONCLUSION: The described diagnostic strategy possibly supports individualized (re-)vaccination schedules based on simple and rapid measurement of serum-based SARS-CoV-2 antibody levels. Our data apply only to WUHAN-type SARS-CoV-2 virus and the current version of the mRNA vaccine from Moderna (Cambridge, MA, USA). Adaptation to other vaccines and more recent SARS-CoV-2 strains will require modification of cut-offs and re-evaluation of sensitivity/specificity.

8.
Msphere ; 6(6):7, 2021.
Article in English | Web of Science | ID: covidwho-1695650

ABSTRACT

Latin America has been severely affected by the COVID-19 pandemic. The COVID-19 burden in rural settings in Latin America is unclear. We performed a cross-sectional, population-based, random-selection SARS-CoV-2 serologic study during March 2021 in the rural population of San Martin region, northern Peru. In total, 563 persons from 288 houses across 10 provinces were enrolled, reaching 0.2% of the total rural population of San Martin. Screening for SARS-CoV-2 IgG antibodies was done using a chemiluminescence immunoassay (CLIA), and reactive sera were confirmed using a SARS-CoV-2 surrogate virus neutralization test (sVNT). Validation of the testing algorithm using prepandemic sera from two regions of Peru showed false-positive results in the CLIA (23/84 sera;27%) but not in the sVNT, highlighting the pitfalls of SARS-CoV-2 antibody testing in tropical regions and the high specificity of the two-step algorithm used in this study. An overall 59.0% seroprevalence (95% confidence interval [CI], 55 to 63%) corroborated intense SARS-CoV-2 spread in San Martin. Seroprevalence rates between the 10 provinces varied from 41.3 to 74.0% (95% CI, 30 to 84%). Higher seroprevalence was not associated with population size, population density, surface area, mean altitude, or poverty index in Spearman correlations. Seroprevalence and reported incidence diverged substantially between provinces, suggesting regional biases of COVID-19 surveillance data. Potentially, limited health care access due to environmental, economic, and cultural factors might lead to undetected infections in rural populations. Additionally, test avoidance to evade mandatory quarantine might affect rural regions more than urban regions. Serologic diagnostics should be pursued in resource-limited settings to inform country-level surveillance and vaccination strategies and to support control measures for COVID-19. IMPORTANCE Latin America is a global hot spot of the COVID-19 pandemic. Serologic studies in Latin America have been mostly performed in urban settings. Rural populations comprise 20% of the total Latin American population. Nevertheless, information on COVID-19 spread in rural settings is scarce. Using a representative population-based seroprevalence study, we detected a high seroprevalence in rural populations in San Martin, northern Peru, in 2021, reaching 41 to 74%. However, seroprevalence and reported incidence diverged substantially between regions, potentially due to limited health care access or test avoidance due to mandatory quarantine. Our results suggest that rural populations are highly affected by SARS-CoV-2 even though they are sociodemographically distinct from urban populations and that highly specific serological diagnostics should be performed in resource-limited settings to support public health strategies of COVID-19 control.

9.
Clin Biochem ; 104: 66-69, 2022 Jun.
Article in English | MEDLINE | ID: covidwho-1664792

ABSTRACT

Salivary matrix is an appealing specimen type for SARS-CoV-2 serology because of ease of collection and potential for concurrent nucleic acid testing. We address the feasibility of salivary matrix to detect anti-SARS-CoV-2 antibodies using two commercially available anti-SARS-CoV-2 Total antibody assays including analytical validations. Matched serum and saliva samples were collected from 10 convalescent COVID-19 patients and tested using a quantitative anti-Spike Total antibody assay and a qualitative anti-Nucleocapsid Total antibody assay from Roche Diagnostics. Both assays were 100% sensitive for COVID-19 history in serum. However, saliva samples were below serum positivity thresholds. We then collected longitudinal salivary samples from a volunteer cohort receiving the Pfizer-BioNTech COVID-19 BNT162b2 vaccine. Saliva was negative for anti-SARS-CoV-2 antibodies at 5 time points after a single dose of vaccine including day 56 when mean (min-max) serum levels of anti-Spike Total antibody were 79.0 U/mL (46.6-110.1) (N = 8). After a second vaccine dose serum-matched samples were beyond the analytical measuring range of the assay (>2500 U/mL), and detection of salivary anti-Spike Total antibody was achieved in all volunteers (12.2 U/mL [2.0-32.7]) (N = 11) 30 days after the second dose. Mean anti-Spike Total antibody levels in serum (1558 U/mL (434->2500)) and saliva (2.6 U/mL (<0.4-11.4)) declined 216-233 days after the first dose of vaccine (P < 0.05); and saliva was 75% sensitive for two doses of vaccination at this latter time point (N = 25). These data suggest commercial assays are capable of detecting vaccine status after two doses of BNT162b2 vaccine up to 6 months and could inform COVID-19 surveillance.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies, Viral , BNT162 Vaccine , COVID-19/prevention & control , COVID-19 Vaccines , Humans
10.
Healthcare (Basel) ; 9(9)2021 Aug 30.
Article in English | MEDLINE | ID: covidwho-1390581

ABSTRACT

BACKGROUND: COVID-19 antibody testing has been shown to be predictive of prior COVID-19 infection and an effective testing tool. The CLUNGENE® SARS-COV-2 VIRUS (COVID-19) IgG/IgM Rapid Test Cassette was evaluated for its utility to aide healthcare professionals. METHOD: Two studies were performed by using the CLUNGENE® Rapid Test. (1) An expanded Point-of-Care (POC) study at two clinical sites was conducted to evaluate 99 clinical subjects: 62 positive subjects and 37 negative subjects were compared to RT-PCR, PPA, and NPA (95% CI). Sensitivity was calculated from blood-collection time following symptom onset. (2) A cross-reactivity study was performed to determine the potential for false-positive results from other common infections. RESULTS: The specificity of subjects with confirmed negative COVID-19 by RT-PCR was 100% (95% CI, 88.4-100.0%). The sensitivity of subjects with confirmed positive COVID-19 by RT-PCR was 96.77% (95% CI, 88.98-99.11%). In the cross-reactivity study, there were no false-positive results due to past infections or vaccinations unrelated to the SARS-CoV-2 virus. CONCLUSION: There is a need for a rapid, user-friendly, and inexpensive on-site monitoring system for diagnosis. The CLUNGENE® Rapid Test is a useful diagnostic test that provides results within 15 min, without high-complexity laboratory instrumentation.

11.
Pathology ; 53(6): 773-779, 2021 Oct.
Article in English | MEDLINE | ID: covidwho-1366648

ABSTRACT

Serological assays for SARS-CoV-2 infection are now widely available for use in diagnostic laboratories. Limited data are available on the performance characteristics in different settings, and at time periods remote from the initial infection. Validation of the Abbott (Architect SARS-CoV-2 IgG), DiaSorin (Liaison SARS-CoV-2 S1/S2 IgG) and Roche (Cobas Elecsys Anti-SARS-CoV-2) assays was undertaken utilising 217 serum samples from 131 participants up to 7 months following COVID-19 infection. The Abbott and DiaSorin assays were implemented into routine laboratory workflow, with outcomes reported for 2764 clinical specimens. Sensitivity and specificity were concordant with the range reported by the manufacturers for all assays. Sensitivity across the convalescent period was highest for the Roche at 95.2-100% (95% CI 81.0-100%), then the DiaSorin at 88.1-100% (95% CI 76.0-100%), followed by the Abbott 68.2-100% (95% CI 53.4-100%). Sensitivity of the Abbott assay fell from approximately 5 months; on this assay paired serum samples for 45 participants showed a significant drop in the signal-to-cut-off ratio and 10 sero-reversion events. When used in clinical practice, all samples testing positive by both DiaSorin and Abbott assays were confirmed as true positive results. In this low prevalence setting, despite high laboratory specificity, the positive predictive value of a single positive assay was low. Comprehensive validation of serological assays is necessary to determine the optimal assay for each diagnostic setting. In this low prevalence setting we found implementation of two assays with different antibody targets maximised sensitivity and specificity, with confirmatory testing necessary for any sample which was positive in only one assay.


Subject(s)
Antibodies, Viral/analysis , COVID-19 Serological Testing/methods , COVID-19/diagnosis , Antibodies, Viral/blood , Humans , Laboratories , Longitudinal Studies , SARS-CoV-2 , Sensitivity and Specificity
12.
Int Health ; 14(1): 18-52, 2022 01 19.
Article in English | MEDLINE | ID: covidwho-1096533

ABSTRACT

As the coronavirus disease 2019 (COVID-19) pandemic continues to rise and second waves are reported in some countries, serological test kits and strips are being considered to scale up an adequate laboratory response. This study provides an update on the kinetics of humoral immune response to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection and performance characteristics of serological protocols (lateral flow assay [LFA], chemiluminescence immunoassay [CLIA] and ELISA) used for evaluations of recent and past SARS-CoV-2 infection. A thorough and comprehensive review of suitable and eligible full-text articles was performed on PubMed, Scopus, Web of Science, Wordometer and medRxiv from 10 January to 16 July 2020. These articles were searched using the Medical Subject Headings terms 'COVID-19', 'Serological assay', 'Laboratory Diagnosis', 'Performance characteristics', 'POCT', 'LFA', 'CLIA', 'ELISA' and 'SARS-CoV-2'. Data from original research articles on SARS-CoV-2 antibody detection ≥second day postinfection were included in this study. In total, there were 7938 published articles on humoral immune response and laboratory diagnosis of COVID-19. Of these, 74 were included in this study. The detection, peak and decline period of blood anti-SARS-CoV-2 IgM, IgG and total antibodies for point-of-care testing (POCT), ELISA and CLIA vary widely. The most promising of these assays for POCT detected anti-SARS-CoV-2 at day 3 postinfection and peaked on the 15th day; ELISA products detected anti-SARS-CoV-2 IgM and IgG at days 2 and 6 then peaked on the eighth day; and the most promising CLIA product detected anti-SARS-CoV-2 at day 1 and peaked on the 30th day. The most promising LFA, ELISA and CLIA that had the best performance characteristics were those targeting total SARS-CoV-2 antibodies followed by those targeting anti-SARS-CoV-2 IgG then IgM. Essentially, the CLIA-based SARS-CoV-2 tests had the best performance characteristics, followed by ELISA then POCT. Given the varied performance characteristics of all the serological assays, there is a need to continuously improve their detection thresholds, as well as to monitor and re-evaluate their performances to assure their significance and applicability for COVID-19 clinical and epidemiological purposes.


Subject(s)
COVID-19 , Humans , Kinetics , Pandemics , SARS-CoV-2 , Sensitivity and Specificity
13.
Clin Lab Med ; 40(4): 603-614, 2020 12.
Article in English | MEDLINE | ID: covidwho-845585

ABSTRACT

The entire spectrum of diagnostic testing, from reagent supply to test performance, has been a major focus during the coronavirus disease 2019 (COVID-19) pandemic. The hope for serologic testing is that it will provide both epidemiologic information about seroprevalence as well as individual information about previous infection. This information is particularly helpful for high-risk individuals who may be outside of the viral shedding window, such as children with suspected multisystem inflammatory syndrome. It is not yet understood whether serologic testing can be interpreted in terms of protective immunity. These concerns must be addressed using highly sensitive and specific tests.


Subject(s)
Betacoronavirus , Clinical Laboratory Techniques/methods , Coronavirus Infections , Pandemics , Pneumonia, Viral , Seroepidemiologic Studies , Betacoronavirus/immunology , Betacoronavirus/isolation & purification , COVID-19 , COVID-19 Testing , Coronavirus Infections/diagnosis , Coronavirus Infections/epidemiology , Coronavirus Infections/immunology , Coronavirus Infections/prevention & control , Humans , Immunity, Humoral/immunology , Pandemics/prevention & control , Pneumonia, Viral/epidemiology , Pneumonia, Viral/immunology , Pneumonia, Viral/prevention & control , Protective Factors , SARS-CoV-2 , Sensitivity and Specificity
14.
Eur J Clin Invest ; 50(10): e13357, 2020 Oct.
Article in English | MEDLINE | ID: covidwho-658264

ABSTRACT

AIMS: To validate the diagnostic accuracy of the Augurix SARS-CoV-2 IgM/IgG rapid immunoassay diagnostic test (RDT) for COVID-19. METHODS: In this unmatched 1:1 case-control study, blood samples from 46 real-time RT-PCR-confirmed SARS-CoV-2 hospitalized cases and 45 healthy donors (negative controls) were studied. Diagnostic accuracy of the IgG RDT was assessed against both an in-house recombinant spike-expressing immunofluorescence assay (rIFA), as an established reference method (primary endpoint), and the Euroimmun SARS-CoV-2 IgG enzyme-linked immunosorbent assays (ELISA) (secondary endpoint). RESULTS: COVID-19 patients were more likely to be male (61% vs 20%; P = .0001) and older (median 66 vs 47 years old; P < .001) than controls. Whole blood IgG-RDT results showed 86% and 93% overall Kendall concordance with rIFA and IgG ELISA, respectively. IgG RDT performances were similar between plasma and whole blood. Overall, RDT sensitivity was 88% (95% confidence interval [95%CI]: 70-96), specificity 98% (95%CI: 90-100), PPV 97% (95%CI: 80-100) and NPV 94% (95%CI: 84-98). The IgG-RDT carried out from 0 to 6 days, 7 to 14 days and > 14 days after the SARS-CoV-2 RT-PCR test displayed 30%, 73% and 100% positivity rates in the COVID-19 group, respectively. When considering samples taken >14 days after RT-PCR diagnosis, NPV was 100% (95%CI:90-100), and PPV was 100% (95%CI:72-100). CONCLUSIONS: The Augurix IgG-RDT done in whole blood displays a high diagnostic accuracy for SARS-CoV-2 IgG in high COVID-19 prevalence settings, where its use could be considered in the absence of routine diagnostic serology facilities.


Subject(s)
Antibodies, Viral/immunology , Betacoronavirus/immunology , Coronavirus Infections/diagnosis , Pneumonia, Viral/diagnosis , Serologic Tests , Spike Glycoprotein, Coronavirus/immunology , Aged , COVID-19 , COVID-19 Testing , COVID-19 Vaccines , Case-Control Studies , Clinical Laboratory Techniques , Female , Fluorescent Antibody Technique , Humans , Immunoglobulin G/immunology , Immunoglobulin M/immunology , Male , Middle Aged , Pandemics , Reverse Transcriptase Polymerase Chain Reaction , SARS-CoV-2 , Sensitivity and Specificity